| EKHVH008BB6V3 | EKHVH008BB9WN | EKHVH008BB6WN | EKHVH016BB6V3 | EKHVH016BB6WN | EKHVH016BB9WN | ||||
|---|---|---|---|---|---|---|---|---|---|
| Sound pressure level | سرعة متوسطة | 0 الضغط الستاتيكي الخارجي | dBA | 28 (9) | 28 (9) | 28 (9) | 28 (15) | 28 (15) | 28 (15) |
| Sound power level | Medium speed | 0 ESP | dBA | 42 | 42 | 42 | 46 | 46 | 46 |
| Dimensions | Unit | العرض | mm | 600 | 600 | 600 | 600 | 600 | 600 |
| العمق | mm | 695 | 695 | 695 | 695 | 695 | 695 | ||
| الارتفاع | mm | 705 | 705 | 705 | 705 | 705 | 705 | ||
| الغلاف | المادة | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | ||
| اللون | Metallic grey | Metallic grey | Metallic grey | Metallic grey | Metallic grey | Metallic grey | |||
| الوزن | الوحدة | kg | 65 | 65 | 65 | 67 | 67 | 67 | |
| Wiring connections | للتوصيل مع واجهة المستخدم | ملاحظة | الحد الأدنى لمقطع الكبل هو 0,75 مم²، والطول الأقصى 500 م | الحد الأدنى لمقطع الكبل هو 0,75 مم²، والطول الأقصى 500 م | الحد الأدنى لمقطع الكبل هو 0,75 مم²، والطول الأقصى 500 م | الحد الأدنى لمقطع الكبل هو 0,75 مم²، والطول الأقصى 500 م | الحد الأدنى لمقطع الكبل هو 0,75 مم²، والطول الأقصى 500 م | الحد الأدنى لمقطع الكبل هو 0,75 مم²، والطول الأقصى 500 م | |
| الكمية | 2 | 2 | 2 | 2 | 2 | 2 | |||
| Electric heater | Current back-up heater | Running current | A | 26 (18) | 13 (20) | 8.7 (19) | 26 (24) | 8.7 (25) | 13 (26) |
| Power supply | Frequency | Hz | 50 | 50 | 50 | ||||
| Voltage | V | 230 | 400 | 400 | 230 | 400 | 400 | ||
| Phase | 1~ | 3 | 3 | 1~ | 3 | 3 | |||
| Notes | (1) - بالتوافق مع ERHQ006BAV3 | (1) - بالتوافق مع ERHQ006BAV3 | (1) - بالتوافق مع ERHQ006BAV3 | (1) - بالتوافق مع ERHQ011BAV3 | (1) - بالتوافق مع ERHQ011BAV3 | (1) - بالتوافق مع ERHQ011BAV3 | |||
| (2) - بالتوافق مع ERLQ006BAV3 | (2) - بالتوافق مع ERLQ006BAV3 | (2) - بالتوافق مع ERLQ006BAV3 | (2) - بالتوافق مع ERLQ011BAV3 | (2) - بالتوافق مع ERLQ011BAV3 | (2) - بالتوافق مع ERLQ011BAV3 | ||||
| (3) - بالتوافق مع ERHQ007BAV3 | (3) - بالتوافق مع ERHQ007BAV3 | (3) - بالتوافق مع ERHQ007BAV3 | (3) - بالتوافق مع ERHQ011BAW1 | (3) - بالتوافق مع ERHQ011BAW1 | (3) - بالتوافق مع ERHQ011BAW1 | ||||
| (4) - بالتوافق مع ERLQ007BAV3 | (4) - بالتوافق مع ERLQ007BAV3 | (4) - بالتوافق مع ERLQ007BAV3 | (4) - بالتوافق مع ERLQ011BAW1 | (4) - بالتوافق مع ERLQ011BAW1 | (4) - بالتوافق مع ERLQ011BAW1 | ||||
| (5) - بالتوافق مع ERHQ008BAV3 | (5) - بالتوافق مع ERHQ008BAV3 | (5) - بالتوافق مع ERHQ008BAV3 | (5) - بالتوافق مع ERHQ014BAV3 | (5) - بالتوافق مع ERHQ014BAV3 | (5) - بالتوافق مع ERHQ014BAV3 | ||||
| (6) - بالتوافق مع ERLQ008BAV3 | (6) - بالتوافق مع ERLQ008BAV3 | (6) - بالتوافق مع ERLQ008BAV3 | (6) - بالتوافق مع ERLQ014BAV3 | (6) - بالتوافق مع ERLQ014BAV3 | (6) - بالتوافق مع ERLQ014BAV3 | ||||
| (7) - Tamb 35° مئوية - LWE 7° مئوية (Dt=5° مئوية) عند السرعة العالية | (7) - Tamb 35° مئوية - LWE 7° مئوية (Dt=5° مئوية) عند السرعة العالية | (7) - Tamb 35° مئوية - LWE 7° مئوية (Dt=5° مئوية) عند السرعة العالية | (7) - بالتوافق مع ERHQ014BAW1 | (7) - بالتوافق مع ERHQ014BAW1 | (7) - بالتوافق مع ERHQ014BAW1 | ||||
| (8) - الحوجلة الجافة/الرطبة 7° مئوية/6° مئوية - LWC 35° مئوية (Dt=5° مئوية) عند السرعة العالية | (8) - الحوجلة الجافة/الرطبة 7° مئوية/6° مئوية - LWC 35° مئوية (Dt=5° مئوية) عند السرعة العالية | (8) - الحوجلة الجافة/الرطبة 7° مئوية/6° مئوية - LWC 35° مئوية (Dt=5° مئوية) عند السرعة العالية | (8) - بالتوافق مع ERLQ014BAW1 | (8) - بالتوافق مع ERLQ014BAW1 | (8) - بالتوافق مع ERLQ014BAW1 | ||||
| (9) - يتم قياس مستوى ضغط الصوت بواسطة مايكروفون على بعد 1 م من الوحدة. إنها قيمة نسبية، تعتمد على المسافة والبيئة الصوتية. | (9) - يتم قياس مستوى ضغط الصوت بواسطة مايكروفون على بعد 1 م من الوحدة. إنها قيمة نسبية، تعتمد على المسافة والبيئة الصوتية. | (9) - يتم قياس مستوى ضغط الصوت بواسطة مايكروفون على بعد 1 م من الوحدة. إنها قيمة نسبية، تعتمد على المسافة والبيئة الصوتية. | (9) - بالتوافق مع ERHQ016BAV3 | (9) - بالتوافق مع ERHQ016BAV3 | (9) - بالتوافق مع ERHQ016BAV3 | ||||
| (10) - إن مستوى ضغط الصوت المذكور صالح للسرعة المتوسطة للمضخة - 0 الضغط الستاتيكي الخارجي / السرعة المتوسطة - التدفق الإسمي /سرعة عالية - تدفق إسمي | (10) - إن مستوى ضغط الصوت المذكور صالح للسرعة المتوسطة للمضخة - 0 الضغط الستاتيكي الخارجي / السرعة المتوسطة - التدفق الإسمي /سرعة عالية - تدفق إسمي | (10) - إن مستوى ضغط الصوت المذكور صالح للسرعة المتوسطة للمضخة - 0 الضغط الستاتيكي الخارجي / السرعة المتوسطة - التدفق الإسمي /سرعة عالية - تدفق إسمي | (10) - بالتوافق مع ERLQ016BAV3 | (10) - بالتوافق مع ERLQ016BAV3 | (10) - بالتوافق مع ERLQ016BAV3 | ||||
| (11) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | (11) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | (11) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | (11) - بالتوافق مع ERHQ016BAW1 | (11) - بالتوافق مع ERHQ016BAW1 | (11) - بالتوافق مع ERHQ016BAW1 | ||||
| (12) - Including piping + PHE + back-up heater; excluding expansion vessel | (12) - Including piping + PHE + back-up heater; excluding expansion vessel | (12) - Including piping + PHE + back-up heater; excluding expansion vessel | (12) - بالتوافق مع ERLQ016BAW1 | (12) - بالتوافق مع ERLQ016BAW1 | (12) - بالتوافق مع ERLQ016BAW1 | ||||
| (13) - انظر الرسم المنفصل لنطاق التشغيل | (13) - انظر الرسم المنفصل لنطاق التشغيل | (13) - انظر الرسم المنفصل لنطاق التشغيل | (13) - Tamb 35° مئوية - LWE 7° مئوية (Dt=5° مئوية) عند السرعة العالية | (13) - Tamb 35° مئوية - LWE 7° مئوية (Dt=5° مئوية) عند السرعة العالية | (13) - Tamb 35° مئوية - LWE 7° مئوية (Dt=5° مئوية) عند السرعة العالية | ||||
| (14) - نطاق التشغيل: فقط مع خزان *KHTS* الاختياري. درجات حرارة الماء الأعلى من 50° مئوية هي بـ BUH فقط. لمزيد من التفاصيل، راجع رسم نطاق التشغيل | (14) - نطاق التشغيل: فقط مع خزان *KHTS* الاختياري. درجات حرارة الماء الأعلى من 50° مئوية هي بـ BUH فقط. لمزيد من التفاصيل، راجع رسم نطاق التشغيل | (14) - نطاق التشغيل: فقط مع خزان *KHTS* الاختياري. درجات حرارة الماء الأعلى من 50° مئوية هي بـ BUH فقط. لمزيد من التفاصيل، راجع رسم نطاق التشغيل | (14) - الحوجلة الجافة/الرطبة 7° مئوية/6° مئوية - LWC 35° مئوية (Dt=5° مئوية) عند السرعة العالية | (14) - الحوجلة الجافة/الرطبة 7° مئوية/6° مئوية - LWC 35° مئوية (Dt=5° مئوية) عند السرعة العالية | (14) - الحوجلة الجافة/الرطبة 7° مئوية/6° مئوية - LWC 35° مئوية (Dt=5° مئوية) عند السرعة العالية | ||||
| (15) - وحدة التزويد بالطاقة الخاصة بالصندوق المائي المذكورة أعلاه هي للسخان الاحتياطي فقط. علبة المفتاح ومضخة الصندوق المائي مرفقة مع الوحدة الخارجية. | (15) - وحدة التزويد بالطاقة الخاصة بالصندوق المائي المذكورة أعلاه هي للسخان الاحتياطي فقط. علبة المفتاح ومضخة الصندوق المائي مرفقة مع الوحدة الخارجية. | (15) - وحدة التزويد بالطاقة الخاصة بالصندوق المائي المذكورة أعلاه هي للسخان الاحتياطي فقط. علبة المفتاح ومضخة الصندوق المائي مرفقة مع الوحدة الخارجية. | (15) - يتم قياس مستوى ضغط الصوت بواسطة مايكروفون على بعد 1 م من الوحدة. إنها قيمة نسبية، تعتمد على المسافة والبيئة الصوتية. | (15) - يتم قياس مستوى ضغط الصوت بواسطة مايكروفون على بعد 1 م من الوحدة. إنها قيمة نسبية، تعتمد على المسافة والبيئة الصوتية. | (15) - يتم قياس مستوى ضغط الصوت بواسطة مايكروفون على بعد 1 م من الوحدة. إنها قيمة نسبية، تعتمد على المسافة والبيئة الصوتية. | ||||
| (16) - يتضمن السخان الكهربائي مرحلتي استطاعة | (16) - يتضمن السخان الكهربائي مرحلتي استطاعة | (16) - يتضمن السخان الكهربائي مرحلتي استطاعة | (16) - إن مستوى ضغط الصوت المذكور صالح للسرعة المتوسطة للمضخة - 0 الضغط الستاتيكي الخارجي / السرعة المتوسطة - التدفق الإسمي /سرعة عالية - تدفق إسمي | (16) - إن مستوى ضغط الصوت المذكور صالح للسرعة المتوسطة للمضخة - 0 الضغط الستاتيكي الخارجي / السرعة المتوسطة - التدفق الإسمي /سرعة عالية - تدفق إسمي | (16) - إن مستوى ضغط الصوت المذكور صالح للسرعة المتوسطة للمضخة - 0 الضغط الستاتيكي الخارجي / السرعة المتوسطة - التدفق الإسمي /سرعة عالية - تدفق إسمي | ||||
| (17) - بالتوافق مع EN/IEC 61000-3-11، قد يكون من الضوري استشارة مشغل شبكة التوزيع للتأكد من أن الجهاز موصول بتغذية ممانعتها Zsys (ممانعة النظام) ≤ Zmax | (17) - بالتوافق مع EN/IEC 61000-3-11، قد يكون من الضوري استشارة مشغل شبكة التوزيع للتأكد من أن الجهاز موصول بتغذية ممانعتها Zsys (ممانعة النظام) ≤ Zmax | (17) - بالتوافق مع EN/IEC 61000-3-11، قد يكون من الضوري استشارة مشغل شبكة التوزيع للتأكد من أن الجهاز موصول بتغذية ممانعتها Zsys (ممانعة النظام) ≤ Zmax | (17) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | (17) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | (17) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | ||||
| (18) - The installer can reduce the capacity of the heater from 6 to 3kW. The current is then reduced from 26 to 13A. Please refer to the installation manual for instructions. | (18) - The installer can reduce the capacity of the heater from 6 to 3kW. The current is then reduced from 26 to 13A. Please refer to the installation manual for instructions. | (18) - The installer can reduce the capacity of the heater from 6 to 3kW. The current is then reduced from 26 to 13A. Please refer to the installation manual for instructions. | (18) - Including piping + PHE + back-up heater; excluding expansion vessel | (18) - Including piping + PHE + back-up heater; excluding expansion vessel | (18) - Including piping + PHE + back-up heater; excluding expansion vessel | ||||
| (19) - يمكن لعامل التركيب إنقاص استطاعة السخان من 6 إلى 2 كيلو واط عندئذٍ سينخفض التيار من 8.7 إلى 5 آمبير يُرجى مراجعة دليل التركيب للحصول على التعليمات. | (19) - يمكن لعامل التركيب إنقاص استطاعة السخان من 6 إلى 2 كيلو واط عندئذٍ سينخفض التيار من 8.7 إلى 5 آمبير يُرجى مراجعة دليل التركيب للحصول على التعليمات. | (19) - يمكن لعامل التركيب إنقاص استطاعة السخان من 6 إلى 2 كيلو واط عندئذٍ سينخفض التيار من 8.7 إلى 5 آمبير يُرجى مراجعة دليل التركيب للحصول على التعليمات. | (19) - راجع رسم نطاق التشغيل لمعرفة الفرق بين الوحدات أحادية الطور والوحدات ثلاثية الطور | (19) - راجع رسم نطاق التشغيل لمعرفة الفرق بين الوحدات أحادية الطور والوحدات ثلاثية الطور | (19) - راجع رسم نطاق التشغيل لمعرفة الفرق بين الوحدات أحادية الطور والوحدات ثلاثية الطور | ||||
| (20) - يمكن لعامل التركيب إنقاص استطاعة السخان من 9 إلى 3 كيلو واط. عندئذٍ سينخفض التيار من 13 إلى 7.5 آمبير. يُرجى مراجعة دليل التركيب للحصول على التعليمات. | (20) - يمكن لعامل التركيب إنقاص استطاعة السخان من 9 إلى 3 كيلو واط. عندئذٍ سينخفض التيار من 13 إلى 7.5 آمبير. يُرجى مراجعة دليل التركيب للحصول على التعليمات. | (20) - يمكن لعامل التركيب إنقاص استطاعة السخان من 9 إلى 3 كيلو واط. عندئذٍ سينخفض التيار من 13 إلى 7.5 آمبير. يُرجى مراجعة دليل التركيب للحصول على التعليمات. | (20) - نطاق التشغيل: فقط مع خزان *KHTS* الاختياري. درجات حرارة الماء الأعلى من 55° مئوية هي بـ BUH فقط. لمزيد من التفاصيل، راجع رسم نطاق التشغيل | (20) - نطاق التشغيل: فقط مع خزان *KHTS* الاختياري. درجات حرارة الماء الأعلى من 55° مئوية هي بـ BUH فقط. لمزيد من التفاصيل، راجع رسم نطاق التشغيل | (20) - نطاق التشغيل: فقط مع خزان *KHTS* الاختياري. درجات حرارة الماء الأعلى من 55° مئوية هي بـ BUH فقط. لمزيد من التفاصيل، راجع رسم نطاق التشغيل | ||||
| (21) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | (21) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | (21) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | (21) - وحدة التزويد بالطاقة الخاصة بالصندوق المائي المذكورة أعلاه هي للسخان الاحتياطي فقط. علبة المفتاح ومضخة الصندوق المائي مرفقة مع الوحدة الخارجية. | (21) - وحدة التزويد بالطاقة الخاصة بالصندوق المائي المذكورة أعلاه هي للسخان الاحتياطي فقط. علبة المفتاح ومضخة الصندوق المائي مرفقة مع الوحدة الخارجية. | (21) - وحدة التزويد بالطاقة الخاصة بالصندوق المائي المذكورة أعلاه هي للسخان الاحتياطي فقط. علبة المفتاح ومضخة الصندوق المائي مرفقة مع الوحدة الخارجية. | ||||
| (22) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase | (22) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase | (22) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase | (22) - Optional electric heater has 2 capacity steps except for the 3V3 model which has only 1 capacity step. | (22) - Optional electric heater has 2 capacity steps except for the 3V3 model which has only 1 capacity step. | (22) - Optional electric heater has 2 capacity steps except for the 3V3 model which has only 1 capacity step. | ||||
| (23) - بالتوافق مع EN/IEC 61000-3-11، قد يكون من الضوري استشارة مشغل شبكة التوزيع للتأكد من أن الجهاز موصول بتغذية ممانعتها Zsys (ممانعة النظام) ≤ Zmax | (23) - بالتوافق مع EN/IEC 61000-3-11، قد يكون من الضوري استشارة مشغل شبكة التوزيع للتأكد من أن الجهاز موصول بتغذية ممانعتها Zsys (ممانعة النظام) ≤ Zmax | (23) - بالتوافق مع EN/IEC 61000-3-11، قد يكون من الضوري استشارة مشغل شبكة التوزيع للتأكد من أن الجهاز موصول بتغذية ممانعتها Zsys (ممانعة النظام) ≤ Zmax | |||||||
| (24) - The installer can reduce the capacity of the heater from 6 to 3kW. The current is then reduced from 26 to 13A. Please refer to the installation manual for instructions. | (24) - The installer can reduce the capacity of the heater from 6 to 3kW. The current is then reduced from 26 to 13A. Please refer to the installation manual for instructions. | (24) - The installer can reduce the capacity of the heater from 6 to 3kW. The current is then reduced from 26 to 13A. Please refer to the installation manual for instructions. | |||||||
| (25) - يمكن لعامل التركيب إنقاص استطاعة السخان من 6 إلى 2 كيلو واط عندئذٍ سينخفض التيار من 8.7 إلى 5 آمبير يُرجى مراجعة دليل التركيب للحصول على التعليمات. | (25) - يمكن لعامل التركيب إنقاص استطاعة السخان من 6 إلى 2 كيلو واط عندئذٍ سينخفض التيار من 8.7 إلى 5 آمبير يُرجى مراجعة دليل التركيب للحصول على التعليمات. | (25) - يمكن لعامل التركيب إنقاص استطاعة السخان من 6 إلى 2 كيلو واط عندئذٍ سينخفض التيار من 8.7 إلى 5 آمبير يُرجى مراجعة دليل التركيب للحصول على التعليمات. | |||||||
| (26) - يمكن لعامل التركيب إنقاص استطاعة السخان من 6 إلى 3 كيلو واط. عندئذٍ سينخفض التيار من 13 إلى 7.5 آمبير. يُرجى مراجعة دليل التركيب للحصول على التعليمات. | (26) - يمكن لعامل التركيب إنقاص استطاعة السخان من 6 إلى 3 كيلو واط. عندئذٍ سينخفض التيار من 13 إلى 7.5 آمبير. يُرجى مراجعة دليل التركيب للحصول على التعليمات. | (26) - يمكن لعامل التركيب إنقاص استطاعة السخان من 6 إلى 3 كيلو واط. عندئذٍ سينخفض التيار من 13 إلى 7.5 آمبير. يُرجى مراجعة دليل التركيب للحصول على التعليمات. | |||||||
| (27) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | (27) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | (27) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | |||||||
| (28) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase | (28) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase | (28) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase | |||||||