جدول المواصفات لـ ERLQ-BV3

ERLQ006BAV3 ERLQ007BAV3 ERLQ008BAV3 ERLQ011BAV3 ERLQ014BAV3 ERLQ016BAV3
Sound pressure level Heating Nom. dBA 48 48 49 49 51 53
  Cooling Nom. dBA 48 48 50 50 52 54
Standard Accessories Installation manual 1 1 1 1 1 1
  سدادة المصرف 1 1 1
Sound power level Heating Nom. dBA 61 61 62 64 64 66
  Cooling Nom. dBA 63 63 63 64 66 69
Refrigerant Charge TCO2Eq 3.5 3.5 3.5 7.7 7.7 7.7
  GWP   2,087.5 2,087.5 2,087.5 2,087.5 2,087.5 2,087.5
  Charge kg 1.7 1.7 1.7 3.7 3.7 3.7
  النوع   R-410A R-410A R-410A R-410A R-410A R-410A
Dimensions Unit العرض mm 825 825 825 900 900 900
    العمق mm 300 300 300 320 320 320
    الارتفاع mm 735 735 735 1,170 1,170 1,170
الوزن الوحدة kg 57 57 57 103 103 103
Piping connections العزل الحراري         Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes
  Liquid القطر الخارجي mm 6.35 6.35 6.35 9.52 9.52 9.52
  غاز القطر الخارجي mm 15.9 15.9 15.9 15.9 15.9 15.9
  Drain OD mm 18 18 18 26 26 26
  Level difference IU - IU Max. م 20 20 20
    IU - OU Max. م       30 30 30
Power supply الطور   1~ 1~ 1~ 1~ 1~ 1~
  Frequency Hz 50 50 50 50 50 50
  الاسم   V3 V3 V3 V3 V3 V3
  Voltage V 230 230 230 230 230 230
Current الفواصم المنصوح بها A 20 20 20 32 32 32
Notes (1) - انظر الرسم المنفصل لنطاق التشغيل (1) - انظر الرسم المنفصل لنطاق التشغيل (1) - انظر الرسم المنفصل لنطاق التشغيل (1) - Down to 3m with recharging of the outdoor unit. Please refer to the installation manual of the outdoor unit. (1) - Down to 3m with recharging of the outdoor unit. Please refer to the installation manual of the outdoor unit. (1) - Down to 3m with recharging of the outdoor unit. Please refer to the installation manual of the outdoor unit.
  (2) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. (2) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. (2) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. (2) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. (2) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. (2) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information.
  (3) - Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase (3) - Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase (3) - Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase (3) - Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase (3) - Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase (3) - Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase
  (4) - يحتوي على غازات الاحتباس الحراري المفلورة (4) - يحتوي على غازات الاحتباس الحراري المفلورة (4) - يحتوي على غازات الاحتباس الحراري المفلورة (4) - يحتوي على غازات الاحتباس الحراري المفلورة (4) - يحتوي على غازات الاحتباس الحراري المفلورة (4) - يحتوي على غازات الاحتباس الحراري المفلورة
Standard Accessories أغلفة برباط       2 2 2