| FNA50A2VEB / FNA50A2VEB / RZQSG100L8Y1B | FNA35A2VEB / FNA35A2VEB / FNA35A2VEB / RZQSG100L8Y1B | FNA50A2VEB / FNA50A2VEB / FNA50A2VEB / RZQSG125L8Y1B | FNA60A2VEB / FNA60A2VEB / RZQSG125L8Y1B | FNA35A2VEB / FNA35A2VEB / FNA35A2VEB / FNA35A2VEB / RZQSG125L8Y1B | ||||
|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 9.50 (1) | 9.50 (1) | 12.0 (1) | 12.0 (1) | 12.0 (1) | |
| تبريد المساحة | استهلاك الطاقة السنوي | كيلو واط ساعي/سنة | 652 | 693 | 875 | 875 | 875 | |
| الاستطاعة | Pdesign | kW | 9.50 | 9.50 | 12.0 | 12.0 | 12.0 | |
| تدفئة المساحة (مناخ معتدل) | الاستطاعة | Pdesign | kW | 7.60 | 7.10 | 7.60 | 7.60 | 7.60 |
| استهلاك الطاقة السنوي | كيلو واط ساعي/سنة | 2,800 | 2,616 | 2,800 | 2,800 | 2,800 | ||
| الفعالية الاسمية | نسبة فعالية استهلاك الطاقة | 3.02 (3) | 2.56 (3) | 2.95 (3) | 2.46 (3) | 2.57 (3) | ||
| عامل الأداء | 3.26 (3) | 2.66 (3) | 3.44 (3) | 3.08 (3) | 2.90 (3) | |||
| التوجيه الخاص بملصق الطاقة | تبريد | B | E | C | E | E | ||
| تدفئة | C | D | B | D | D | |||
| Heating capacity | Nom. | kW | 10.8 (2) | 10.8 (2) | 13.5 (2) | 13.5 (2) | 13.5 (2) | |
| تبريد المساحة | SEER | 5.10 | 4.80 | 4.80 | 4.80 | 4.80 | ||
| فئة فعالية استهلاك الطاقة | A | B | B | B | B | |||
| تدفئة المساحة (مناخ معتدل) | SCOP/A | 3.80 | 3.80 | 3.80 | 3.80 | 3.80 | ||
| فئة فعالية استهلاك الطاقة | A | A | A | A | A | |||
| Notes | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m | |||
| (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m | ||||
| (3) - نسبة فعالية استهلاك الطاقة/عامل الأداء بحسب Eurovent 2012، للاستخدام خارج دول الاتحاد الأوروبي فقط | (3) - نسبة فعالية استهلاك الطاقة/عامل الأداء بحسب Eurovent 2012، للاستخدام خارج دول الاتحاد الأوروبي فقط | (3) - نسبة فعالية استهلاك الطاقة/عامل الأداء بحسب Eurovent 2012، للاستخدام خارج دول الاتحاد الأوروبي فقط | (3) - نسبة فعالية استهلاك الطاقة/عامل الأداء بحسب Eurovent 2012، للاستخدام خارج دول الاتحاد الأوروبي فقط | (3) - نسبة فعالية استهلاك الطاقة/عامل الأداء بحسب Eurovent 2012، للاستخدام خارج دول الاتحاد الأوروبي فقط | ||||