جدول المواصفات لـ FTXG-JA / RXLG-K

FTXG25JV1BA / RXLG25K2V1B FTXG25JV1BA / RXLG25K3V1B FTXG35JV1BA / RXLG35K2V1B FTXG35JV1BA / RXLG35K3V1B FTXG50JV1BA / RXLG50K2V1B FTXG50JV1BA / RXLG50K3V1B
Cooling capacity Min. kW 1.3 1.3 1.4 1.4 1.7 1.7
  Max. kW 3.0 3.0 3.8 3.8 5.3 5.3
  Nom. kW 2.5 (3) 2.5 (2) 3.5 (3) 3.5 (2) 5.0 (2) 5.0 (2)
Piping connections Liquid القطر الخارجي mm 6.35 6.35 6.35 6.35 6.35 6.35
  غاز القطر الخارجي mm 9.52 9.52 9.52 9.52 12.7 12.7
  Drain OD mm 16 أو 18 16 أو 18 16 أو 18 16 أو 18 18.0 18.0
الفعالية الاسمية استهلاك الطاقة السنوي kWh 280 280 445 445 780 780
  نسبة فعالية استهلاك الطاقة   4.46 4.46 (1) 3.93 3.93 (1) 3.21 (1) 3.21 (1)
  عامل الأداء   4.36 4.36 (1) 4.04 4.04 (1) 3.63 (1) 3.63 (1)
  التوجيه الخاص بملصق الطاقة تبريد   A A A A A A
    تدفئة   A A A A A A
Heating capacity Nom. kW 3.4 (4) 3.4 (3) 4.0 (4) 4.0 (3) 5.8 (3) 5.8 (3)
  Min. kW 1.3 1.3 1.4 1.4 1.7 1.7
  Max. kW 4.5 4.5 5.0 5.0 6.5 6.5
Notes (1) - ملصق الطاقة: مدرج من A (أعلى فعالية) إلى G (أقل فعالية) (1) - نسبة فعالية استهلاك الطاقة/عامل الأداء بحسب Eurovent 2012، للاستخدام خارج دول الاتحاد الأوروبي فقط (1) - ملصق الطاقة: مدرج من A (أعلى فعالية) إلى G (أقل فعالية) (1) - نسبة فعالية استهلاك الطاقة/عامل الأداء بحسب Eurovent 2012، للاستخدام خارج دول الاتحاد الأوروبي فقط (1) - نسبة فعالية استهلاك الطاقة/عامل الأداء بحسب Eurovent 2012، للاستخدام خارج دول الاتحاد الأوروبي فقط (1) - نسبة فعالية استهلاك الطاقة/عامل الأداء بحسب Eurovent 2012، للاستخدام خارج دول الاتحاد الأوروبي فقط
  (2) - استهلاك الطاقة السنوي: استناداً إلى معدل استخدام 500 ساعة تشغيل في السنة بالحمل الكامل (الشروط الأسمية) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - استهلاك الطاقة السنوي: استناداً إلى معدل استخدام 500 ساعة تشغيل في السنة بالحمل الكامل (الشروط الأسمية) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m
  (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m
  (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (4) - 220 فولت (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (4) - 220 فولت (4) - 220 فولت (4) - 220 فولت
  (5) - SL: The silent fan level of the air flow rate setting (5) - 230 فولت (5) - SL: The silent fan level of the air flow rate setting (5) - 230 فولت (5) - 230 فولت (5) - 230 فولت
  (6) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. (6) - 240 فولت (6) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. (6) - 240 فولت (6) - 240 فولت (6) - 240 فولت
  (7) - 220 فولت (7) - الفعالية الإسمية: التبريد عند 35°/27° حمل إسمي، التدفئة عند 7°/20° حمل إسمي (7) - 220 فولت (7) - الفعالية الإسمية: التبريد عند 35°/27° حمل إسمي، التدفئة عند 7°/20° حمل إسمي (7) - الفعالية الإسمية: التبريد عند 35°/27° حمل إسمي، التدفئة عند 7°/20° حمل إسمي (7) - الفعالية الإسمية: التبريد عند 35°/27° حمل إسمي، التدفئة عند 7°/20° حمل إسمي
  (8) - 230 فولت   (8) - 230 فولت
  (9) - 240 فولت   (9) - 240 فولت
  (10) - الفعالية الإسمية: التبريد عند 35°/27° حمل إسمي، التدفئة عند 7°/20° حمل إسمي   (10) - الفعالية الإسمية: التبريد عند 35°/27° حمل إسمي، التدفئة عند 7°/20° حمل إسمي