| FVXG25K2V1B / RXLG25K3V1B | FVXG25K2V1B / RXLG25K2V1B | FVXG35K2V1B / RXLG35K3V1B | FVXG35K2V1B / RXLG35K2V1B | FVXG50K2V1B / RXLG50K2V1B | FVXG50K2V1B / RXLG50K3V1B | ||||
|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Min. | kW | 1.3 | 1.3 | 1.4 | 1.4 | 1.7 | 1.7 | |
| Max. | kW | 3.0 | 3.0 | 3.8 | 3.8 | 5.6 | 5.6 | ||
| Nom. | kW | 2.5 (2) | 2.5 (3) | 3.5 (2) | 3.5 (3) | 5.0 (2) | 5.0 (2) | ||
| Piping connections | Liquid | القطر الخارجي | mm | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 |
| غاز | القطر الخارجي | mm | 9.5 | 9.5 | 9.5 | 9.5 | 12.7 | 12.7 | |
| Drain | OD | mm | 18.0 | 18.0 | 18.0 | 18.0 | |||
| الفعالية الاسمية | استهلاك الطاقة السنوي | kWh | 275 | 275 | 475 | 476 | 760 | 760 | |
| نسبة فعالية استهلاك الطاقة | 4.55 | 4.55 | 3.68 | 3.68 | 3.29 (1) | 3.29 (1) | |||
| عامل الأداء | 4.36 | 4.36 | 3.72 | 3.72 | 3.67 (1) | 3.67 (1) | |||
| التوجيه الخاص بملصق الطاقة | تبريد | A | A | A | A | A | A | ||
| تدفئة | A | A | A | A | A | A | |||
| Heating capacity | Nom. | kW | 3.4 (3) | 3.4 (4) | 4.5 (3) | 4.5 (4) | 5.8 (3) | 5.8 (3) | |
| Min. | kW | 1.3 | 1.3 | 1.4 | 1.4 | 1.7 | 1.7 | ||
| Max. | kW | 4.5 | 4.5 | 5.0 | 5.0 | 8.1 | 8.1 | ||
| Notes | (1) - نسبة فعالية استهلاك الطاقة/عامل الأداء بحسب Eurovent 2012، للاستخدام خارج دول الاتحاد الأوروبي فقط | (1) - ملصق الطاقة: مدرج من A (أعلى فعالية) إلى G (أقل فعالية) | (1) - نسبة فعالية استهلاك الطاقة/عامل الأداء بحسب Eurovent 2012، للاستخدام خارج دول الاتحاد الأوروبي فقط | (1) - ملصق الطاقة: مدرج من A (أعلى فعالية) إلى G (أقل فعالية) | (1) - نسبة فعالية استهلاك الطاقة/عامل الأداء بحسب Eurovent 2012، للاستخدام خارج دول الاتحاد الأوروبي فقط | (1) - نسبة فعالية استهلاك الطاقة/عامل الأداء بحسب Eurovent 2012، للاستخدام خارج دول الاتحاد الأوروبي فقط | |||
| (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) | (2) - استهلاك الطاقة السنوي: استناداً إلى معدل استخدام 500 ساعة تشغيل في السنة بالحمل الكامل (الشروط الأسمية) | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) | (2) - استهلاك الطاقة السنوي: استناداً إلى معدل استخدام 500 ساعة تشغيل في السنة بالحمل الكامل (الشروط الأسمية) | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | ||||
| (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) | (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) | (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | ||||
| (4) - 220 فولت | (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) | (4) - 220 فولت | (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) | (4) - 220 فولت | (4) - 220 فولت | ||||
| (5) - 230 فولت | (5) - الفعالية الإسمية: التبريد عند 35°/27° حمل إسمي، التدفئة عند 7°/20° حمل إسمي | (5) - 230 فولت | (5) - الفعالية الإسمية: التبريد عند 35°/27° حمل إسمي، التدفئة عند 7°/20° حمل إسمي | (5) - 230 فولت | (5) - 230 فولت | ||||
| (6) - 240 فولت | (6) - 240 فولت | (6) - 240 فولت | (6) - 240 فولت | ||||||
| (7) - الفعالية الإسمية: التبريد عند 35°/27° حمل إسمي، التدفئة عند 7°/20° حمل إسمي | (7) - الفعالية الإسمية: التبريد عند 35°/27° حمل إسمي، التدفئة عند 7°/20° حمل إسمي | (7) - الفعالية الإسمية: التبريد عند 35°/27° حمل إسمي، التدفئة عند 7°/20° حمل إسمي | (7) - الفعالية الإسمية: التبريد عند 35°/27° حمل إسمي، التدفئة عند 7°/20° حمل إسمي | ||||||