FCAG100BVEB / FCAG100BVEB / RZA200D7Y1B |
FCAG125BVEB / FCAG125BVEB / RZA250D7Y1B |
FCAG50BVEB / FCAG50BVEB / FCAG50BVEB / FCAG50BVEB / RZA200D7Y1B |
FCAG60BVEB / FCAG60BVEB / FCAG60BVEB / FCAG60BVEB / RZA250D7Y1B |
FCAG71BVEB / FCAG71BVEB / FCAG71BVEB / RZA200D7Y1B |
Cooling capacity
|
Nom.
|
kW
|
19.0 (1)
|
22.0 (1)
|
19.0 (1)
|
22.0 (1)
|
19.0 (1)
|
Space cooling
|
SEER
|
|
6.53
|
6.44
|
7.16
|
6.95
|
6.32
|
|
ηs,c
|
%
|
258
|
254
|
283
|
275
|
250
|
|
Annual energy consumption
|
kWh/a
|
1,746
|
2,052
|
1,592
|
1,898
|
1,804
|
|
Capacity
|
Pdesign
|
kW
|
19.0
|
22.0
|
19.0
|
22.0
|
19.0
|
Space heating (Average climate)
|
Capacity
|
Pdesign
|
kW
|
11.2
|
12.1
|
11.2
|
12.1
|
11.2
|
|
SCOP/A
|
|
4.10
|
4.10
|
4.10
|
4.10
|
4.10
|
|
Annual energy consumption
|
kWh/a
|
3,824
|
4,132
|
3,825
|
4,132
|
3,824
|
|
ηs,h
|
%
|
161
|
161
|
161
|
161
|
161
|
Heating capacity
|
Nom.
|
kW
|
22.4 (2)
|
24.0 (2)
|
22.4 (2)
|
24.0 (2)
|
22.4 (2)
|
Notes
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|